# Splunk HEC Logging Configuration

The `splunk-hec-logging` plugin sends request and response logs to Splunk HTTP Event Collector in batches and supports customizable log formats.<!-- --> <!-- -->Configuration covers plugin parameters and plugin metadata.

## Parameters[​](#parameters "Direct link to Parameters")

See plugin [common configurations](https://docs.api7.ai/apisix/reference/plugin-common-configurations.md) for configuration options available to all plugins.

* endpoint

  object\[object]

  required

  ***

  Splunk HEC endpoint configurations.

  * uri

    string

    required

    ***

    Splunk HEC event collector API endpoint.

  * token

    string

    required

    ***

    Splunk HEC authentication token. API7 Gateway encrypts the value with AES at rest. APISIX encrypts it before etcd storage when `apisix.data_encryption.enable_encrypt_fields` is enabled.

  * channel

    string

    ***

    Splunk HEC send data channel identifier. For more information, see [About HTTP Event Collector Indexer Acknowledgment](https://docs.splunk.com/Documentation/Splunk/latest/Data/AboutHECIDXAck).

  * timeout

    integer

    default: `10`

    ***

    Splunk HEC send data timeout in seconds.

  * keepalive\_timeout

    integer

    default: `60000`

    valid value:

    greater than or equal to 1000

    ***

    Keepalive timeout in milliseconds.

* ssl\_verify

  boolean

  default: `true`

  ***

  If true, verify the TLS certificate when the HEC endpoint uses HTTPS. Set to false only for a trusted evaluation endpoint with a self-signed certificate.

* log\_format

  object

  ***

  Custom log format using key-value pairs in JSON format. Values can reference [built-in variables](https://docs.api7.ai/apisix/reference/built-in-variables.md).

  In APISIX from 3.15.0, log format nested structures are supported up to five levels deep. In API7 Enterprise, only flat key-value structures are supported; nested structures are not yet supported.

  You can also configure log format on a global scale using the [plugin metadata](https://docs.api7.ai/apisix/key-concepts/plugin-metadata.md), which configures the log format for all `splunk-hec-logging` plugin instances. If the log format configured on the individual plugin instance differs from the log format configured on plugin metadata, the log format configured on the individual plugin instance takes precedence. See the [example](https://docs.api7.ai/hub/splunk-hec-logging.md#log-request-and-response-headers-with-plugin-metadata) for more details.

* log\_format\_extra

  object

  ***

  Additional fields to add to the default log entry, using key-value pairs in JSON format. Values can reference [built-in variables](https://docs.api7.ai/apisix/reference/built-in-variables.md). A configured field does not overwrite an existing default field. A plugin instance takes precedence over plugin metadata; setting an empty object on the instance disables the metadata value. When `log_format` is configured, `log_format_extra` is ignored.

  Introduced in API7 Enterprise 3.9.15 and 3.10.2, and APISIX 3.18.0.

* name

  string

  default: `splunk-hec-logging`

  ***

  Unique identifier of the plugin for the batch processor.

* batch\_max\_size

  integer

  default: `1000`

  valid value:

  greater than 0

  ***

  The number of log entries allowed in one batch. Once reached, the batch will be sent to Splunk HEC. Setting this parameter to 1 means immediate processing.

* inactive\_timeout

  integer

  default: `5`

  valid value:

  greater than 0

  ***

  The maximum time in seconds to wait for new logs before sending the batch to the logging service. The value should be smaller than `buffer_duration`.

* buffer\_duration

  integer

  default: `60`

  valid value:

  greater than 0

  ***

  The maximum time in seconds from the earliest entry allowed before sending the batch to the logging service.

* retry\_delay

  integer

  default: `1`

  valid value:

  greater than or equal to 0

  ***

  The time interval in seconds to retry sending the batch to the logging service if the batch was not successfully sent.

* max\_retry\_count

  integer

  default: `0`

  valid value:

  greater than or equal to 0

  ***

  The maximum number of unsuccessful retries allowed before dropping the log entries.

## Plugin Metadata[​](#plugin-metadata "Direct link to Plugin Metadata")

* log\_format

  object

  ***

  Custom log format using key-value pairs in JSON format. Values can reference [built-in variables](https://docs.api7.ai/apisix/reference/built-in-variables.md).

  In APISIX from 3.15.0, log format nested structures are supported up to five levels deep. In API7 Enterprise, only flat key-value structures are supported; nested structures are not yet supported.

* log\_format\_extra

  object

  ***

  Additional fields to add to the default log entry, using key-value pairs in JSON format. Values can reference [built-in variables](https://docs.api7.ai/apisix/reference/built-in-variables.md). A configured field does not overwrite an existing default field. A plugin instance takes precedence over plugin metadata; setting an empty object on the instance disables the metadata value. When `log_format` is configured, `log_format_extra` is ignored.

  Introduced in API7 Enterprise 3.9.15 and 3.10.2, and APISIX 3.18.0.

* max\_pending\_entries

  integer

  default: `8192`

  valid value:

  greater than or equal to 1

  ***

  Maximum number of entries waiting in the batch processor. New entries are discarded when the backlog reaches the limit.

  Introduced in API7 Enterprise 3.8.17 and APISIX 3.15.0.

  The default changed to `8192` in APISIX 3.18.0 and in API7 Enterprise 3.9.19 on the 3.9 line and 3.10.6 on the 3.10 line. In API7 Enterprise 3.9.18 and 3.10.5, and in earlier APISIX versions, omitting the parameter leaves the backlog unlimited.

  See [Batch Processor](https://docs.api7.ai/apisix/reference/batch-processor.md#configure-the-pending-entry-limit) for sizing and verification guidance.